Cleveland KGL-100 100 Gallon Gas Kettle
The Cleveland KGL-100 100 Gallon Gas Kettle is a top-of-the-line cooking equipment that is designed to enhance your kitchen's efficiency and productivity. Made from high-quality stainless steel, this kettle is built to last and withstand the rigors of commercial kitchen use.
With a large 100 gallon capacity, the Cleveland KGL-100 is perfect for cooking large batches of soups, stews, and sauces, making it an ideal choice for catering businesses, restaurants, and other food service operations. Equipped with a powerful gas burner, this kettle heats up quickly and maintains a consistent temperature throughout the cooking process, ensuring that your food is cooked to perfection every time.
The Cleveland KGL-100 is also incredibly user-friendly, with intuitive controls and an easy-to-read temperature gauge. Its removable strainer basket and durable, corrosion-resistant finish make it easy to clean and maintain, while its sturdy design ensures that it will provide years of reliable performance.
Whether you are cooking for a large group or need to keep food warm and ready to serve, the Cleveland KGL-100 100 Gallon Gas Kettle is the perfect addition to any commercial kitchen. Its advanced features and exceptional performance make it the go-to choice for chefs and food service professionals alike.
The Cleveland KGL-100 Leg Type Gas-Fired Kettles-Splash Proof Series has a capacity of 100 Gallons / 375 liters. It has high efficiency Power Burner Heating System (62% to 65% efficiency). Fast Heat-up and Recovery Time, 140M BTUs on 40 gallon models, 190M BTUs on 60 gallon and larger. Insulated Heat Exchanger. Automatic Ignition System. Steam jacket permanently filled with treated, distilled water. Venting and/or refilling not required. Solid State Controls, for Temperature and Low Water Safety, in a plug-in Control Module. Control Panel includes precise, consistent temperature control: less than ± 1°C variance (ideal for simmering), L.E.D. Indicators for Heat Cycle and Low Water Warning, Power on/off Switch. Front mounted combination Pressure/Vacuum Gauge. Type 304 Stainless Steel with #4 finish on kettle and supports. 2" diameter Tangent Draw-Off Valve with Drain Strainer. Support Legs with level adjustable feet, flanged for floor bolting. Spring-assisted, hinged, rotatable, domed Stainless Steel Cover. 50 PSI Steam Jacket Rating and Safety valve. Standard voltage is 115 volts, 60 Hz, single-phase, supplied with cord and plug. Standard for natural gas operation. Faucet Mounting Bracket (FBK).
The Options & Accessories include Type 316 Stainless Steel Kettle Liner for high acid food products (316). Hot and Cold Water Faucet with Swing Spout (DPK). Cooking Baskets and Tri-Basket Supports (BS and TBS). Drain Strainers (DS-). 3" diameter Tangent Draw-off Valve with Drain Strainer (TD3). Kettle Accessory Kit (KAK) includes Clean-up Brush(CB), 36" Kettle Paddle (KP), 36" Kettle Whip(KW), 36" Kettle Brush (KB), Draw-off Brush (DB), and 24 oz. Ladle (KL). Automatic Water Meter (GMF or LMF), Measuring Strip (MS), Option for Propane Gas operation, Correctional Package, and Heat Deflector Shield (HS001).
Cleveland KGL-100 Leg Type Gas-Fired Kettles-Splash Proof Series is the #1 choice of restaurateurs, cafeteria owners, foodservice directors, cooks, and chefs!
Did You Know?
"Corded kettles" generally use detachable IEC C15 and C16 connections. "Cordless kettles" became popular in the 1980s and 1990s consisting of a plastic base that connects to the mains outlet and a separate kettle. They both have electrical contacts that connect to supply power to the kettle when it is placed on top of the base, and the kettle can be easily detached to allow movement to the sink and elsewhere.SPECIFICATIONS
Right of design improvement or modification, as warranted, is reserved.
PRODUCT:
Cleveland Leg Type Gas-Fired Kettles-Splash Proof SeriesMODEL NO.:
KGL-100OVERALL DIMENSIONS (L x W x H):
44"(1118mm) x 43-1/2"(1105mm) x 47-1/2"(1207mm)CAPACITY:
1,600 servings (8 oz. serving size)GAS:
Manufacturer must be notified if unit will be operated above 2,000 ft. altitude.Specification - Natural Gas - Propane
Piping: 3/4" N.P.T. - Piping: 3/4" N.P.T.
Supply pressure minimum: 4.00" W.C. - 4.00" W.C.
Supply pressure maximum: 14.00" W.C. - 14.00" W.C.
B.T.U. RATING:
190,000ELECTRIC:
120V-1 Phase, 60 Hz, 10 ampsWATER:
1/2" dia. Soft Copper Tubing (each). When ordered with optional faucet.CLEARANCES:
Right = 3"
Left = 3"
Rear = 3"
Allow 6" space minimum from rear and sides when located near combustible walls. 12" recommended on right side for service
NOTES:
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer.RECOMMENDED FLOOR SLOPE:
1" (26 mm) per 4' (1220 mm)PIPE DRAIN RECOMMENDED:
Min. valve size plus 1" (26 mm)- California Residents click here for Proposition 65 warning